Industrial Air Quality, Inc
OsKar Modular Filter Unit

Oskar Modular Filter

Modular unit with plenum

download data sheet on Oskar Modular filter unit (pdf)

Oskar’s Modular filter is designed to filtrate air from dry applications. Applications such as welding smoke, metal dusts, some pharmaceutical dusts, and most non-explosive dry dust’s can be handled by Oskar’s Modular Filter. The units are modular in construction and can be ordered in 1,2,3 or even more modules. The modules can also be refitted in the field by removing panels and bolting additional units together. Thus making it ideal for growing companies. The MF Filter is not designed for excess temperatures, explosive contaminants or flammable gases. thanks to its high filtration efficiency, filtered air can be returned to the working area. Caution should be taken when filtering contaminants that also contain harmful gases. In this case air should be filtered then exhausted to the outside. The MF Filter also shouldn’t be used to filtrate air, which is laden with more than then 2.5% of oilmist or emulsions.

The main components of the filter consist of a base with integral waste drawer, filter cartridge housing a cleaning system enclosure. The Inlet plenum to the filter is mounted on the short side of the filter housing. Each module houses two round washable spun bond polyester cartridges cartridges. The cleaning system enclosure consists of a compressed air tank, diaphragm valve, solenoid valve and connecting components as well as 2 venturi tubes for venturi assisted cleaning of the filters. The top plate is adapted for either a fan mounting directly to the unit or an outlet flange connection to a remote fan. he OsKar MF Filter is fabricated of Powder coated painted steel.

The OsKar filter electrical and cleaning systems controls comes as standard with:

  • thermal overload protection for fan motor
  • automatic timed cleaning with offline pulsing after shutdown.
Technical Data
Modular unit technical drawing
Dimensions
Length 42.5 in / 1080 mm
Width 21.2 in / 540 mm
Height (without inlet) 79.52 in / 2020 mm
Inlet Diameter 10 in / 250 mm
Outlet diameter 10 in / 250 mm
Weight 394 lbs 179 kg
Waste drawer 0.6 ft3 / 17 liters
Filters
Preliminary - metal mesh sparktrap 21x17x0.8 [in]
540x440x20 [mm]
2 pcs of cartridges (standard filtering area per cartridge 32 m2). Type of filtering media from paper, polyester to teflon coated and anitstatic. 12.8x39.3[in]
325x1000 [mm]
Pressured air
Air pressure 85-100 PSI / 5.5-6.5 atm
Air connection 1/2" NPT
Compressed air tank capacity 0.89 ft3 / 25 l